Availability: | |
---|---|
Quantity: | |
1. Insulation: Ethylene Propylene Diene Monomer (EPDM) or EP compound
2. Jacket: rubber or CPE or CP compound
3. Voltage: 300 Volt
4. -40ºC to +90ºC
5. 90ºC 300 Volt UL /CSA Portable Cord
6. Excellent resistance to oil and moisture Good tensile strength, elongation and aging characteristics High flexibility Excellent abrasion resistance Water-resistant UL Listed and CSA Certified for indoor and outdoor use.
The 'S' and 'J' letters in each of these types mean that they are 'J'unior 'S'ervice. Junior service simply means that the voltage rating of the cord is 300 volts. A single 'O' designates an oil resistant outer jacket, while the double 'OO' stands for oil-resistant insulation and an oil-resistant outer jacket. Finally, the 'W' stands for weather and water-resistant and is CSA approved for indoor or outdoor use.
Insulation thickness: 0.76 mm
Jacket wall thickness: 0.76 mm
Cable spec | Conductor | Insulation O.D. | Jacket O.D. | Current |
18AWGx2C | 41/0.16 | 2.80 | 7.35 | 10A |
16AWGx2C | 26/0.254 | 3.10 | 7.95 | 13A |
14AWGx2C | 41/0.254 | 3.50 | 8.70 | 15A |
12AWGx2C | 65/0.254 | 4.00 | 10.50 | 20A |
18AWGx3C | 41/0.16 | 2.80 | 7.80 | 10A |
16AWGx3C | 26/0.254 | 3.10 | 8.40 | 13A |
14AWGx3C | 41/0.254 | 3.50 | 9.30 | 15A |
12AWGx3C | 65/0.254 | 4.00 | 11.00 | 20A |
18AWGx4C | 41/0.16 | 2.80 | 8.60 | 10A |
16AWGx4C | 26/0.254 | 3.10 | 9.20 | 13A |
14AWGx4C | 41/0.254 | 3.50 | 10.30 | 15A |
12AWGx4C | 65/0.254 | 4.00 | 12.10 | 20A |
18AWGx5C | 41/0.16 | 2.80 | 9.30 | 10A |
16AWGx5C | 26/0.254 | 3.10 | 10.10 | 13A |
14AWGx5C | 41/0.254 | 3.50 | 11.10 | 15A |
12AWGx5C | 65/0.254 | 4.00 | 13.25 | 20A |
1. Insulation: Ethylene Propylene Diene Monomer (EPDM) or EP compound
2. Jacket: rubber or CPE or CP compound
3. Voltage: 300 Volt
4. -40ºC to +90ºC
5. 90ºC 300 Volt UL /CSA Portable Cord
6. Excellent resistance to oil and moisture Good tensile strength, elongation and aging characteristics High flexibility Excellent abrasion resistance Water-resistant UL Listed and CSA Certified for indoor and outdoor use.
The 'S' and 'J' letters in each of these types mean that they are 'J'unior 'S'ervice. Junior service simply means that the voltage rating of the cord is 300 volts. A single 'O' designates an oil resistant outer jacket, while the double 'OO' stands for oil-resistant insulation and an oil-resistant outer jacket. Finally, the 'W' stands for weather and water-resistant and is CSA approved for indoor or outdoor use.
Insulation thickness: 0.76 mm
Jacket wall thickness: 0.76 mm
Cable spec | Conductor | Insulation O.D. | Jacket O.D. | Current |
18AWGx2C | 41/0.16 | 2.80 | 7.35 | 10A |
16AWGx2C | 26/0.254 | 3.10 | 7.95 | 13A |
14AWGx2C | 41/0.254 | 3.50 | 8.70 | 15A |
12AWGx2C | 65/0.254 | 4.00 | 10.50 | 20A |
18AWGx3C | 41/0.16 | 2.80 | 7.80 | 10A |
16AWGx3C | 26/0.254 | 3.10 | 8.40 | 13A |
14AWGx3C | 41/0.254 | 3.50 | 9.30 | 15A |
12AWGx3C | 65/0.254 | 4.00 | 11.00 | 20A |
18AWGx4C | 41/0.16 | 2.80 | 8.60 | 10A |
16AWGx4C | 26/0.254 | 3.10 | 9.20 | 13A |
14AWGx4C | 41/0.254 | 3.50 | 10.30 | 15A |
12AWGx4C | 65/0.254 | 4.00 | 12.10 | 20A |
18AWGx5C | 41/0.16 | 2.80 | 9.30 | 10A |
16AWGx5C | 26/0.254 | 3.10 | 10.10 | 13A |
14AWGx5C | 41/0.254 | 3.50 | 11.10 | 15A |
12AWGx5C | 65/0.254 | 4.00 | 13.25 | 20A |
Home | About Us | Products | Service | Contact Us